Manley ELOP+ - Stereo Limiter and compresor
Manley ELOP+ - Stereo Limiter and compresor
Limited availability
- 10:1 Limiter and 3:1 Compressor ratios
- All-tube audio path uses 5751 and 6922 dual triodes
- Balanced Manley IRON® transformer-coupled XLR Inputs
- XLR impedance-balanced outputs
- BYPASS switches and AUTOMUTE with warm-up delay
- Large illuminated VU meters read Gain Reduction or Output levels
- STEREO LINK
- Side-Chain High-Pass Filter
- Standby Power Consumption: 0.5 Watts
- Universal internal power supply operates worldwide 90-250V~AC 50/60Hz
- ALL-TUBE audio path using a 5751 for gain, 6922 White Follower output tube (one each per channel)
- Silent Conductive Plastic GAIN control.
- Balanced MANLEY IRON Transformer coupled XLR input.
- Input impedance: 14 kOhms
- Maximum input level: +18dBu or 4.8V RMS @ 0.01% THD
- Hi-current White Follower Impedance Balanced XLR output.
- Output impedance=150 Ohms
- Maximum Output with 100 kOhm load= +30dBu @.009%THD+N, BW 22Hz-22Khz, 1Khz sine
- Maximum Output with 600 Ohm load= +20dBu @.015%THD+N, BW 22Hz-22Khz, 1Khz sine
- Output Headroom (Referenced to +4dBu)= 26dB
- Frequency Response= -0.15dB @ 10Hz, -0.1dB @ 20KHz
- Total Harmonic Distortion (1kHz sine @ +4dBu, BW 22Hz-22kHz) = 0.004 % THD+N
- Noise Floor Limiter Bypass= -90dBu (BW 22Hz-22kHz)
- Noise Floor Limiter Engaged= -88dBu (BW 22Hz-22kHz) Input set to Unity gain
- Dynamic Range= 118dB
- Signal to Noise Ratio = 92dB (Referenced to +4dBu)
- Bypass mode = Signal goes thru ALL-TUBE audio path (Bypasses limiter) this is not a “hardwire bypass”
- Unity Gain= Set Input Attenuator @ 1:00 o’clock
- Maximum Gain= 13 dB
- Common-Mode Rejection Ratio (CMRR)= 77dB (BW 22Hz-22Khz, +4dBu, 1Khz sine)
- Limiter Ratio= 10:1
- Compressor Ratio= 3:1
- Limiter: Attack= 15ms
- Limiter Release= 200ms
- Compressor: Attack= 75ms Release= 200ms
- Attack/Release times measured under following conditions: 4dB of Gain Reduction, 1kHz sine, +4dbu Input level, to 63% of total.
- Attack times are faster with higher input levels and heavier gain reduction. Typically for complete release, release times increases up to a couple of seconds, depending upon the amount of previous reduction.
- Maximum Limiting (with +4dBu 1Khz sine)= 12dB
- Maximum Compression (with +4dBu 1Khz sine)= 6dB
- Side-Chain High Pass Filter= 80Hz (Internal user adjust jumper to 150Hz)
- Automute warmup delay=30 seconds
- Operating mains voltage= 90 to 254 VAC (internal universal power supply)
- Mains voltage Frequency= 50-60 Hz
- Power consumption= 26 Watts
- Dimensions= (w,d,h) 19" x 7 x 3 1⁄2" (occupies 2u)
- Unit weight= 9.5 Ib
- Shipping weight= 10 Ib
Product delivery details Manley ELOP+ - Stereo Limiter and compresor
Shipment from Warsaw, Poland.
Delivery to
If you wish to see more accurate shipping methods available in your location, fill the fields above.
Ask question about product
About manufacturer Manley
![Manley Manley](https://imuzyczny.pl/media/manufacturerblog/manley-logo_3.png)
Manley jest amerykańską firmą założoną pod koniec lat 80. przez EveAnne Mankley. Marka od początku dokłada wszelkich starań, aby dostarczyć sprzęt najwyższej jakości tworzony w oparciu o tradycję. Rozwiązania Manley skupia się na projektowaniu urządzeń potrzebnych do nagrywania, miksowania, masteringu i odtwarzenia.